{"id":7636,"date":"2026-09-11T00:00:04","date_gmt":"2026-09-10T16:00:04","guid":{"rendered":"https:\/\/www.wonvolt.com\/?p=7636"},"modified":"2026-09-10T12:22:50","modified_gmt":"2026-09-10T04:22:50","slug":"factory-peak-shaving-with-bidirectional-pcs-how-to-match-power-battery-capacity-and-control-logic","status":"publish","type":"post","link":"https:\/\/www.wonvolt.com\/fr\/news\/factory-peak-shaving-with-bidirectional-pcs-how-to-match-power-battery-capacity-and-control-logic\/","title":{"rendered":"R\u00e9duction des pics de consommation en usine avec PCS bidirectionnel\u00a0: Comment adapter la capacit\u00e9 de la batterie et la logique de contr\u00f4le"},"content":{"rendered":"<p>L'\u00e9cr\u00eatement des pointes de consommation en usine gr\u00e2ce \u00e0 un syst\u00e8me de transfert de puissance bidirectionnel fonctionne lorsque la puissance de l'onduleur, l'\u00e9nergie des batteries et les programmes de contr\u00f4le correspondent aux pics de demande du site. Une usine qui ach\u00e8te une capacit\u00e9 de batterie excessive mais une puissance de transfert de puissance insuffisante ne peut pas se d\u00e9charger assez rapidement pour r\u00e9duire un pic de demande ponctuel. Un syst\u00e8me dot\u00e9 d'une puissance de transfert de puissance \u00e9lev\u00e9e mais d'une batterie faiblement charg\u00e9e risque d'atteindre sa limite de charge avant la fin de la p\u00e9riode tarifaire. La conception pratique consiste \u00e0 cartographier le profil de charge, \u00e0 identifier la dur\u00e9e des pics, \u00e0 r\u00e9server une plage de charge de fonctionnement et \u00e0 s\u00e9lectionner des \u00e9quipements capables de fournir la puissance requise de mani\u00e8re r\u00e9p\u00e9t\u00e9e. Cette approche permet de r\u00e9duire les co\u00fbts li\u00e9s \u00e0 la demande tout en pr\u00e9servant la dur\u00e9e de vie des batteries et en assurant la stabilit\u00e9 des charges de production.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-7633\" src=\"https:\/\/www.wonvolt.com\/wp-content\/uploads\/2026\/09\/Factory-Peak-Shaving-with-Bidirectional-PCS-How-to-Match-Power-Battery-Capacity-and-Control-Logic.webp\" alt=\"R\u00e9duction des pics de consommation en usine avec PCS bidirectionnel\u00a0: Comment adapter la capacit\u00e9 de la batterie et la logique de contr\u00f4le\" width=\"750\" height=\"499\" srcset=\"https:\/\/www.wonvolt.com\/wp-content\/uploads\/2026\/09\/Factory-Peak-Shaving-with-Bidirectional-PCS-How-to-Match-Power-Battery-Capacity-and-Control-Logic.webp 750w, https:\/\/www.wonvolt.com\/wp-content\/uploads\/2026\/09\/Factory-Peak-Shaving-with-Bidirectional-PCS-How-to-Match-Power-Battery-Capacity-and-Control-Logic-300x200.webp 300w, https:\/\/www.wonvolt.com\/wp-content\/uploads\/2026\/09\/Factory-Peak-Shaving-with-Bidirectional-PCS-How-to-Match-Power-Battery-Capacity-and-Control-Logic-18x12.webp 18w, https:\/\/www.wonvolt.com\/wp-content\/uploads\/2026\/09\/Factory-Peak-Shaving-with-Bidirectional-PCS-How-to-Match-Power-Battery-Capacity-and-Control-Logic-600x399.webp 600w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><\/p>\n<h2><strong><b>Le probl\u00e8me de puissance et d'\u00e9nergie \u00e0 l'origine du rasage des pics<\/b><\/strong><\/h2>\n<p>L'\u00e9cr\u00eatement des pointes de consommation est avant tout un probl\u00e8me de puissance, puis un probl\u00e8me d'\u00e9nergie. Le syst\u00e8me de contr\u00f4le de puissance (PCS) r\u00e9gule la puissance de charge ou de d\u00e9charge instantan\u00e9e en kilowatts. La batterie d\u00e9termine la dur\u00e9e pendant laquelle cette puissance peut \u00eatre maintenue, en kilowattheures. Si une ligne de production g\u00e9n\u00e8re un pic de demande de 400 kW pendant 30 minutes, l'\u00e9nergie minimale id\u00e9ale est de 200 kWh avant prise en compte de la r\u00e9serve, des pertes de conversion, des variations de temp\u00e9rature et des limites li\u00e9es \u00e0 l'\u00e9tat de charge (SOC). Le PCS doit \u00e9galement pouvoir fournir l'\u00e9nergie n\u00e9cessaire \u00e0 la d\u00e9charge de 400 kW, en tenant compte de la marge de s\u00e9curit\u00e9 pour la r\u00e9ponse du syst\u00e8me et les erreurs de mesure.<\/p>\n<h3><strong><b>Consultez la courbe de charge avant de choisir le mat\u00e9riel.<\/b><\/strong><\/h3>\n<p>Utilisez les donn\u00e9es d'intervalle du compteur d'alimentation ou d'un analyseur de qualit\u00e9 de l'\u00e9nergie install\u00e9 sur site. Des donn\u00e9es sur 15 minutes constituent un bon point de d\u00e9part, mais des mesures \u00e0 la minute r\u00e9v\u00e8lent les d\u00e9marrages brefs des moteurs, les compresseurs, les soudeuses et les pics de consommation li\u00e9s aux proc\u00e9d\u00e9s par lots, qui peuvent dispara\u00eetre des relev\u00e9s de demande moyenne. Notez la consommation maximale mensuelle, la dur\u00e9e typique des pics, le nombre de pics par jour et la charge minimale pendant la p\u00e9riode tarifaire.<\/p>\n<h3><strong><b>Distinguer les pics brefs des pics soutenus<\/b><\/strong><\/h3>\n<p>Un pic de consommation bref peut n\u00e9cessiter une puissance de PCS \u00e9lev\u00e9e et une consommation d'\u00e9nergie mod\u00e9r\u00e9e. Un pic de deux heures en apr\u00e8s-midi requiert davantage d'\u00e9nergie utile de la batterie et une gestion optimis\u00e9e \u00e9vitant les d\u00e9charges pr\u00e9matur\u00e9es. Ne basez pas le dimensionnement sur la valeur la plus \u00e9lev\u00e9e si celle-ci provient d'un d\u00e9faut ou d'un test ponctuel. Comparez au moins trois journ\u00e9es de production repr\u00e9sentatives et v\u00e9rifiez si le m\u00eame \u00e9quipement est \u00e0 l'origine du pic \u00e0 chaque fois.<\/p>\n<h3><strong><b>Convertir la fen\u00eatre tarifaire en un plan d'exp\u00e9dition<\/b><\/strong><\/h3>\n<p>D\u00e9finissez un plafond d'importation du r\u00e9seau inf\u00e9rieur au seuil de facturation de la demande, puis laissez le syst\u00e8me de gestion de l'\u00e9nergie (EMS) commander au syst\u00e8me de contr\u00f4le de puissance (PCS) de maintenir l'importation proche de ce plafond. Pr\u00e9voyez une r\u00e9serve d'\u00e9tat de charge (SOC) pour les pics impr\u00e9vus et les besoins de secours. Le document de conception doit pr\u00e9ciser l'\u00e9tat de charge minimal et maximal, le d\u00e9lai de d\u00e9clenchement, la vitesse de mont\u00e9e en charge et la p\u00e9riode de facturation de la r\u00e9cup\u00e9ration.<\/p>\n<h2><strong><b>Comment adapter la puissance du PCS aux charges d'usine<\/b><\/strong><\/h2>\n<p>Le choix du PCS doit se faire en fonction de la charge \u00e0 contr\u00f4ler, et non en fonction des caract\u00e9ristiques de la batterie. Un onduleur bidirectionnel doit absorber l'\u00e9nergie de charge pendant les p\u00e9riodes de faible charge et fournir l'\u00e9nergie de d\u00e9charge pendant les pics de consommation. Il doit \u00e9galement \u00eatre compatible en termes de tension, de protection, de communication et de fonctions de soutien au r\u00e9seau.<\/p>\n<h3><strong><b>Utiliser la marge de s\u00e9curit\u00e9 pour les moteurs et l'erreur de mesure<\/b><\/strong><\/h3>\n<p>Si la r\u00e9duction vis\u00e9e est de 300 kW, le choix d'un convertisseur de puissance (PCS) d'une puissance nominale de 300 kW ne laisse aucune marge pour les erreurs de capteurs, la consommation auxiliaire ou le d\u00e9marrage simultan\u00e9 d'une seconde charge. Confirmez une marge sp\u00e9cifique au projet apr\u00e8s avoir examin\u00e9 la courbe de charge sur une minute et la courbe de surcharge du PCS. Demandez dans l'offre technique la puissance nominale continue, la puissance admissible en cas de surcharge de courte dur\u00e9e, la plage de facteur de puissance et le temps de r\u00e9ponse.<\/p>\n<h3><strong><b>Choisir une architecture pour l'expansion<\/b><\/strong><\/h3>\n<p>Un seul PCS de grande capacit\u00e9 simplifie la commande et la maintenance, tandis que plusieurs unit\u00e9s PCS en parall\u00e8le offrent une capacit\u00e9 \u00e9chelonn\u00e9e et un fonctionnement partiel lorsqu'une unit\u00e9 est hors service. Le fonctionnement en parall\u00e8le exige une strat\u00e9gie de commande claire, un micrologiciel adapt\u00e9, une protection s\u00e9lective et un test de mise en service pour le courant de circulation. Pour les projets \u00e9volutifs, les modules PCS r\u00e9duisent le risque de devoir remplacer l'onduleur complet lors de l'augmentation de la production.<\/p>\n<p>Pour une usine \u00e9valuant une large gamme de puissance, le <a href=\"https:\/\/www.wonvolt.com\/fr\/product\/100kw-1mw-battery-inverter-bidirectional-pcs100-1000-us\/\"><strong><u>Inverteur de batterie 100KW-1MW PCS100-1000-US bidirectionnel<\/u><\/strong><\/a>\u00a0Ce produit de r\u00e9f\u00e9rence est pertinent pour la conversion bidirectionnelle de puissance des batteries. Veuillez confirmer la tension alternative finale, le sch\u00e9ma de protection, le profil de surcharge, le protocole de communication et les exigences du r\u00e9seau local avant de passer commande.<\/p>\n<h1><strong><b>La capacit\u00e9 de la batterie est une d\u00e9cision d'exp\u00e9dition<\/b><\/strong><\/h1>\n<p>La capacit\u00e9 de la batterie doit couvrir l'\u00e9nergie \u00e0 dissiper, major\u00e9e des pertes et d'une r\u00e9serve \u00e9vitant un fonctionnement en limite de charge. Un calcul simple permet de d\u00e9terminer l'\u00e9nergie utile\u00a0: \u00e9nergie utile = r\u00e9duction de la puissance de pointe cible x dur\u00e9e de d\u00e9charge. Si l'usine a besoin de 250\u00a0kW pendant 1,2\u00a0heure, la capacit\u00e9 minimale requise est de 300\u00a0kWh. Le cahier des charges doit pr\u00e9ciser si la capacit\u00e9 indiqu\u00e9e est nominale ou utile, et sous quelle temp\u00e9rature, quel taux de d\u00e9charge (C-rate) et quelle tension de fin de d\u00e9charge.<\/p>\n<h2><strong><b>Choisissez un cluster qui peut \u00e9voluer avec le site<\/b><\/strong><\/h2>\n<p><strong><u>Le <\/u><\/strong><a href=\"https:\/\/www.wonvolt.com\/fr\/product\/100-215kwh-lithium-battery-cluster-51-2v-280ah\/\"><strong><u>Groupe de batteries au lithium de 100 \u00e0 261 kWh<\/u><\/strong><\/a>\u00a0Ce syst\u00e8me peut servir de module de base pour la planification du stockage commercial et industriel. Sa configuration de 51,2 V et 314 Ah permet de comparer le nombre de racks, la conception du bus CC et l'\u00e9nergie utilisable. Veuillez v\u00e9rifier la combinaison finale des modules, les limites du syst\u00e8me de gestion technique du b\u00e2timent (GTB), le mode de refroidissement, la puissance nominale du bo\u00eetier et les conditions de garantie dans le devis.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter  wp-image-7630\" src=\"https:\/\/www.wonvolt.com\/wp-content\/uploads\/2026\/09\/100-261kWh-Lithium-Battery-Cluster.webp\" alt=\"Groupe de batteries au lithium de 100 \u00e0 261 kWh\" width=\"502\" height=\"502\" srcset=\"https:\/\/www.wonvolt.com\/wp-content\/uploads\/2026\/09\/100-261kWh-Lithium-Battery-Cluster.webp 750w, https:\/\/www.wonvolt.com\/wp-content\/uploads\/2026\/09\/100-261kWh-Lithium-Battery-Cluster-300x300.webp 300w, https:\/\/www.wonvolt.com\/wp-content\/uploads\/2026\/09\/100-261kWh-Lithium-Battery-Cluster-150x150.webp 150w, https:\/\/www.wonvolt.com\/wp-content\/uploads\/2026\/09\/100-261kWh-Lithium-Battery-Cluster-12x12.webp 12w, https:\/\/www.wonvolt.com\/wp-content\/uploads\/2026\/09\/100-261kWh-Lithium-Battery-Cluster-600x600.webp 600w, https:\/\/www.wonvolt.com\/wp-content\/uploads\/2026\/09\/100-261kWh-Lithium-Battery-Cluster-100x100.webp 100w\" sizes=\"(max-width: 502px) 100vw, 502px\" \/><\/p>\n<h3><strong><b>Tableau de r\u00e9f\u00e9rence des dimensions<\/b><\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"144\">Observation du site<\/td>\n<td width=\"144\">Implication du PCS<\/td>\n<td width=\"144\">Cons\u00e9quences sur la batterie<\/td>\n<td width=\"144\">V\u00e9rifiez avant de commander<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">Pics brefs de moins de 15 minutes<\/td>\n<td width=\"144\">Prioriser la puissance (kW), le temps de r\u00e9ponse et la capacit\u00e9 de surcharge.<\/td>\n<td width=\"144\">Capacit\u00e9 utile mod\u00e9r\u00e9e en kWh avec r\u00e9serve<\/td>\n<td width=\"144\">Trac\u00e9 de charge et latence du capteur en une minute<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">Pics d'une dur\u00e9e de 30 \u00e0 120 minutes<\/td>\n<td width=\"144\">La notation continue doit maintenir le plafond d'importation cible.<\/td>\n<td width=\"144\">La capacit\u00e9 \u00e9nerg\u00e9tique devient un facteur limitant<\/td>\n<td width=\"144\">kWh utilisables \u00e0 la temp\u00e9rature et au niveau de charge indiqu\u00e9s<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">Plusieurs pics chaque jour<\/td>\n<td width=\"144\">V\u00e9rifier la puissance de recharge et le temps de r\u00e9cup\u00e9ration<\/td>\n<td width=\"144\">La strat\u00e9gie de cycle influe sur le d\u00e9bit journalier<\/td>\n<td width=\"144\">Limites du BMS, gestion thermique, garantie<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">Extension de production pr\u00e9vue<\/td>\n<td width=\"144\">Utiliser une architecture PCS parall\u00e8le ou modulaire<\/td>\n<td width=\"144\">Laissez de l'espace et une marge de conception CC<\/td>\n<td width=\"144\">Communication, protection, plan futur des racks<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong><b>D\u00e9tails relatifs aux commandes, \u00e0 la s\u00e9curit\u00e9 et \u00e0 la mise en service<\/b><\/strong><\/h2>\n<p>Le syst\u00e8me de gestion de l'\u00e9nergie (EMS) ne doit pas r\u00e9agir \u00e0 la moindre fluctuation. Une zone morte \u00e9vite les cycles inutiles, tandis qu'une limitation de la rampe r\u00e9duit les variations brusques sur le bus de l'usine. Le syst\u00e8me de contr\u00f4le de puissance (PCS) doit \u00eatre coordonn\u00e9 avec le transformateur, les batteries de condensateurs, les g\u00e9n\u00e9rateurs et la logique de transfert des charges critiques de l'usine. Si un g\u00e9n\u00e9rateur d\u00e9marre pendant un incident sur le r\u00e9seau, l'EMS doit bloquer les commandes de charge et de d\u00e9charge contradictoires.<\/p>\n<h3><strong><b>Deux contr\u00f4les sur le terrain qui \u00e9vitent des reprises co\u00fbteuses<\/b><\/strong><\/h3>\n<p>Premi\u00e8rement, v\u00e9rifiez l'emplacement du compteur. Un capteur install\u00e9 en aval d'une branche de process importante risque de ne pas mesurer la demande utilis\u00e9e pour la facturation. Comparez les relev\u00e9s du syst\u00e8me de gestion de l'\u00e9nergie (EMS) avec ceux du compteur de facturation lors d'une variation de charge contr\u00f4l\u00e9e. Deuxi\u00e8mement, testez le comportement thermique au taux de d\u00e9charge pr\u00e9vu. La temp\u00e9rature de la batterie, la capacit\u00e9 du syst\u00e8me de climatisation et l'espacement des armoires peuvent limiter la puissance utilisable, m\u00eame si les caract\u00e9ristiques \u00e9lectriques semblent ad\u00e9quates.<\/p>\n<p><a href=\"https:\/\/www.wonvolt.com\/fr\/\"><strong><u>WonVolt<\/u><\/strong><\/a>\u00a0prend en charge la planification au niveau de la solution gr\u00e2ce \u00e0 son <a href=\"https:\/\/www.wonvolt.com\/fr\/solution\/industrial-commercial\/\"><strong><u>solution de stockage d'\u00e9nergie industrielle et commerciale<\/u><\/strong><\/a>\u00a0ressources. Pr\u00e9parer le sch\u00e9ma unifilaire, les donn\u00e9es de demande sur douze mois, les r\u00e8gles tarifaires, la plage de temp\u00e9rature ambiante, les exigences en mati\u00e8re de s\u00e9curit\u00e9 incendie et la r\u00e9serve d'exploitation privil\u00e9gi\u00e9e.<\/p>\n<h2><strong><b>Quand Peak Shaving n'est pas le bon premier investissement<\/b><\/strong><\/h2>\n<p>L'\u00e9cr\u00eatement des pointes de consommation peut s'av\u00e9rer peu avantageux lorsque les co\u00fbts li\u00e9s \u00e0 la demande sont faibles, les pics impr\u00e9visibles ou lorsque le site ne dispose pas de plage horaire de recharge optimale. Il est \u00e9galement inadapt\u00e9 si le local \u00e9lectrique ne r\u00e9pond pas aux exigences en mati\u00e8re de d\u00e9gagement, de ventilation, de s\u00e9paration coupe-feu ou de cheminement des c\u00e2bles. Dans ces cas, il convient de corriger la mesure de la charge, d'am\u00e9liorer la planification des processus ou d'\u00e9valuer un syst\u00e8me de secours plus modeste avant d'opter pour un important parc de batteries.<\/p>\n<p>Une conception compl\u00e8te doit pr\u00e9senter la courbe de demande de r\u00e9f\u00e9rence, la courbe post-d\u00e9part pr\u00e9vue, les cycles annuels, la consommation auxiliaire, les hypoth\u00e8ses de remplacement et une analyse de sensibilit\u00e9 pour une r\u00e9duction de pointe inf\u00e9rieure aux pr\u00e9visions. WonVolt peut vous accompagner dans la documentation du projet et la mise en service. <a href=\"https:\/\/www.wonvolt.com\/fr\/about-wonvolt\/contact-us\/\"><strong><u>canal de contact<\/u><\/strong><\/a>.<\/p>\n<h2><strong><b>FAQ (questions fr\u00e9quentes)<\/b><\/strong><\/h2>\n<h3><strong><b>Quelle capacit\u00e9 de batterie est n\u00e9cessaire pour une puissance de pointe de 500 kW en usine ?<\/b><\/strong><\/h3>\n<p>Commencez par la dur\u00e9e. Une pointe de 500 kW durant une heure n\u00e9cessite 500 kWh d'\u00e9nergie utilisable avant pertes et prise en compte de la r\u00e9serve. Confirmez la dur\u00e9e \u00e0 partir des donn\u00e9es d'intervalle, puis appliquez la fen\u00eatre d'\u00e9tat de charge (SOC) et les hypoth\u00e8ses de rendement.<\/p>\n<h3><strong><b>Un syst\u00e8me de climatisation de 100 kW peut-il r\u00e9duire un pic de demande de 300 kW\u00a0?<\/b><\/strong><\/h3>\n<p>Il peut r\u00e9duire l'apport au r\u00e9seau d'environ 100 kW en fonctionnement continu. Il ne peut pas \u00e9liminer la totalit\u00e9 du pic de consommation \u00e0 moins d'installer une capacit\u00e9 de stockage d'\u00e9nergie suppl\u00e9mentaire ou de g\u00e9rer la charge en parall\u00e8le.<\/p>\n<h3><strong><b>Quelle plage de SOC convient \u00e0 un rasage quotidien optimal ?<\/b><\/strong><\/h3>\n<p>Respectez les limites de fonctionnement, les conditions de temp\u00e9rature et les termes de garantie du fournisseur de la batterie. Conservez une r\u00e9serve d\u00e9finie et \u00e9vitez de d\u00e9charger jusqu'au niveau de charge minimal absolu en fonctionnement normal.<\/p>\n<h3><strong><b>Une usine doit-elle utiliser un seul grand PCS ou plusieurs unit\u00e9s plus petites\u00a0?<\/b><\/strong><\/h3>\n<p>Une seule unit\u00e9 simplifie la coordination. Les unit\u00e9s parall\u00e8les am\u00e9liorent la mise en service et la disponibilit\u00e9 partielle, mais n\u00e9cessitent des commandes adapt\u00e9es, une protection s\u00e9lective et un test de mise en service document\u00e9.<\/p>\n<h3><strong><b>Quels documents faut-il demander avant de commander un PCS bidirectionnel\u00a0?<\/b><\/strong><\/h3>\n<p>Demandez la fiche technique, la courbe d'efficacit\u00e9, le profil de surcharge, les fonctions de code r\u00e9seau, les param\u00e8tres de protection, le sch\u00e9ma de communication, les d\u00e9gagements d'installation, le plan de test, les conditions de garantie et le sch\u00e9ma unifilaire.<\/p>\n<h1><strong><b>Une prochaine \u00e9tape pratique<\/b><\/strong><\/h1>\n<p>Commencez par \u00e9tablir la courbe de charge et d\u00e9finissez le plafond cible d'injection sur le r\u00e9seau. Comparez ensuite la puissance du PCS, l'\u00e9nergie utilisable de la batterie, la r\u00e9serve d'\u00e9tat de charge (SOC), les limites thermiques et le p\u00e9rim\u00e8tre de mise en service sur une base commune. WonVolt peut vous aider \u00e0 transformer ces donn\u00e9es en une architecture de stockage d'\u00e9nergie par batterie adapt\u00e9e au site, plut\u00f4t que d'imposer \u00e0 ce dernier une puissance nominale standard.<\/p>","protected":false},"excerpt":{"rendered":"<p>Factory peak shaving with a bidirectional PCS works when inverter power, battery energy, and control schedules match the site&#8217;s demand peaks. A factory that buys too much battery but too little PCS power cannot discharge quickly enough to reduce a short demand spike. A system with large PCS power but a shallow battery may hit [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7633,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-7636","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.wonvolt.com\/fr\/wp-json\/wp\/v2\/posts\/7636","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wonvolt.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.wonvolt.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.wonvolt.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wonvolt.com\/fr\/wp-json\/wp\/v2\/comments?post=7636"}],"version-history":[{"count":1,"href":"https:\/\/www.wonvolt.com\/fr\/wp-json\/wp\/v2\/posts\/7636\/revisions"}],"predecessor-version":[{"id":7637,"href":"https:\/\/www.wonvolt.com\/fr\/wp-json\/wp\/v2\/posts\/7636\/revisions\/7637"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wonvolt.com\/fr\/wp-json\/wp\/v2\/media\/7633"}],"wp:attachment":[{"href":"https:\/\/www.wonvolt.com\/fr\/wp-json\/wp\/v2\/media?parent=7636"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.wonvolt.com\/fr\/wp-json\/wp\/v2\/categories?post=7636"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.wonvolt.com\/fr\/wp-json\/wp\/v2\/tags?post=7636"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}